Understanding Common ClearCase Failures
Dynamic View Slowness
Dynamic views are mounted over the MVFS (Multi-Version File System). Slowness may stem from overloaded network storage, view staleness, or improper configuration of the view server process.
- Symptoms: File access latency, IDE freeze, failed builds
- Impact: Developer friction, CI/CD delays, NFS saturation
View Corruption and Missing Elements
View storage may become inconsistent due to disk issues, unclean shutdowns, or improper use of view-private files. The result is missing checkouts, orphaned config specs, or inaccessible branches.
VOB Mount Failures
VOBs (Versioned Object Bases) may fail to mount if the storage server is offline, permissions are misconfigured, or registry data is stale. The failure halts access to core versioned artifacts.
Architecture Overview and Dependencies
ClearCase Components
- VOB Server: Stores versioned data
- View Server: Hosts snapshot and dynamic views
- Registry Server: Tracks VOB and view locations
- MVFS: Kernel module for dynamic view access
Key Dependencies
- NFS or SAN storage for VOBs and views
- ClearCase ALBD (Atria Location Broker Daemon)
- Hostname resolution and Windows services (if on Windows)
Diagnostics and Monitoring
Check ALBD and MVFS Status
cleartool lsview cleartool lsvob cleartool lsserver ls -l /view cleartool catcs
Ensure ALBD is running:
net start "IBM Rational ClearCase ALBD"
Dynamic View Debugging
- Use
cleartool setview
to enter the view and validate file access - Check for errors in
view_log
andalbd_log
- Run
ctdoctor
on Windows orcleartool checkvob
on UNIX to validate configuration
VOB Mount Verification
mount cleartool mount /vobs/project_vob cleartool describe -long vob:/project_vob
Verify storage host availability and network reachability:
ping vob_server_hostname netstat -an | grep 371 rpcinfo -p vob_server
Common Misconfigurations and Root Causes
Stale Views
Views not used for long periods or left open during host shutdowns can corrupt. Snapshot views may desync if used across multiple environments without rebase.
Registry or Storage Path Changes
Changing registry entries or moving view/VOB storage without updating ClearCase registry causes hard-to-diagnose failures.
Antivirus Interference
On Windows, antivirus tools can lock MVFS-mounted files or slow down dynamic view resolution.
Improper Config Spec Changes
Manually editing config specs without validation can cause elements to disappear or show incorrect versions.
Step-by-Step Troubleshooting and Recovery
1. Validate View Integrity
cleartool lsview -long viewname cleartool describe -long view:viewname cleartool lsvtree filename cleartool lsprivate -invob
2. Repair Corrupted Views
- Delete and recreate snapshot views
- Rebase or reimport config spec from a stable baseline
- Remove view-private files blocking updates
3. Remount and Re-register VOBs
cleartool umount /vobs/project_vob cleartool mount /vobs/project_vob cleartool register -vob \host\vobstore\project.vbs cleartool mktag -vob -tag /vobs/project_vob \host\vobstore\project.vbs
4. Clean View-Private File Conflicts
cleartool ls -rec -view_only | grep -i .keep find . -name "*.contrib" -delete
5. Restart ClearCase Services
- Restart ALBD and MVFS modules
- Ensure hostname resolution (especially on Windows)
- Restart view_server or reboot dynamic view clients
Best Practices for Long-Term ClearCase Stability
- Automate regular VOB backups and use
cleartool protectvob
- Set TTLs on stale views and archive unused ones
- Schedule
checkvob
andcheckview
runs monthly - Use consistent config spec templates with version baselines
- Avoid dynamic views in build pipelines—use snapshot or UCM streams
Conclusion
ClearCase is complex but reliable when maintained diligently. Issues like view corruption, slow dynamic performance, and inaccessible VOBs can cripple development pipelines if left unchecked. With targeted diagnostics, proper configuration hygiene, and scheduled maintenance, teams can keep ClearCase stable even in high-regulation environments. Migrating away from ClearCase should be considered long term, but robust troubleshooting and best practices ensure continuity today.
FAQs
1. Why is my dynamic view extremely slow?
Likely causes include MVFS contention, high network latency, overloaded view servers, or antivirus scans. Consider switching to snapshot views for performance-critical operations.
2. How do I detect orphaned views?
Use cleartool lsview -long
and compare with actual storage directories. Orphaned views appear in registry but point to missing directories or hosts.
3. Can ClearCase views be shared across hosts?
Snapshot views can be copied with care, but dynamic views are host-dependent. Shared use without rebasing or updating leads to corruption.
4. What causes VOB mount failures after a reboot?
Missing registry entries, unmounted network storage, or ALBD not running can cause VOBs to fail mounting. Always validate service and network layer readiness post-reboot.
5. Is there a way to modernize ClearCase without full migration?
Yes. Introduce a hybrid model with Git for new modules while keeping ClearCase for legacy code. Use scripting to sync snapshots to Git where feasible.